Skip to main content
Feb 26, 2016 / Haseeb Jamal -

5 Travel Myths You Need to Stop Believing Right Now

Feb 26, 2016 / Haseeb Jamal -

Canal Comes Alive with Lighted Boat Parade.

Design of Transmission Tower in SAP2000

Define > material, steel, modifying fy = 36 ksi. Fx = 58ksi. Define > load cases add D.L & in L.L Self wt =0 Define > add default combo select steel & convert to user check boxes. Select top most joints.

Bridge Designing Video Tutorials - Free Downloads

Course Outline for Bridge Engg Spring 2009 a. Video Files: Anchor-Block.MPG BROOKLYN(FULL).MPG GoldenGate(Full).MPG History.MPG INTRODUTION.MPG Stone-Arch-action.MPG Tacoma-narrow.MPG Truss-action.MPG b. LectureNo.1.pptLectureNo.1-A.pptLectureNo.2.pptLecture No.1AUpdatedLecture No. 2Updated Lecture No.3Lecture No.3

Steps in Construction of Multi Storey Buildings

Since the thermal expansion of concrete is different from that of masonry. The interface between the concrete and the masonry is liable to crack. To avoid this crack the chicken wire mesh is used to avoid the crack and also provides the better grip for Masonry with concrete. Similarly when the drainage pipes are laid along with the outer wall then again the connection between the pipe and

Design procedure for sanitary sewers

Calculate the average wastewater flow, Qavg = (70-80) % of average water consumption. Select a peak factor, PF = [(18+√P)/(4+√P)], where P = population in thousands. Calculate the peak wastewater flow, Qpeak = (PF * Qavg)

Design & Construction of Steel Structures

it is the ability to redistribute the load. Simple beam is determinate. Fixed beam is indeterminate by 2 degrees so it has two redundant actions. fixed supported beam is more better as indeterminate structure can redistribute the load. When load increases support becomes plastic and it turns into a simply supported beam. But simply supported does not go through the stage of plastic

Uses & Design of Flow Equalization Tank

Flow equalization is method used to overcome the operational problems and flow rate variations to improve the performance of downstream processes and to reduce the size & cost of downstream treatment facilities. To prevent flow rate, temperature, and contaminant concentrations from varying widely, flow equalization is often used. Variations occur

Design & Beam Analysis using SAP2000

Define> load cases, add live load. Define > add default combo. Check concrete & convert to user editable boxes. Select beams

Design of Reponse Spectrum using SAP2000

Define > function > response spectrum. Add new function, name = Rs. Define > analysis cases. Add new function, new = Rsx Analysis case = Response spectrum. Acceleration U1 Rs 32.2

Design of Precast Parabolic Channels in Peshawar

Discrepancy feature is the conveyance losses (35 to 50%). Irrigation system of KPK (Province of Pakistan) is facing severe Operational problems including water scarcity, water logging, and salinity. Reason was due to the traditional brick lining. The following steps are involved

Culverts Types, Design, Installation and Materials

A culvert is an opening through an embankment for the conveyance of water by mean of pipe or an enclosed channel. OR It is a transverse and totally enclosed drain under a road or railway. Pipe culverts are made of smooth steel, corrugated metal, or concrete material. Their primary purpose is to convey water under roads, although a variety of wildlife use them as

Design and Selection of GeoTextiles

After a detailed study of research carried out here and in Europe on both conventional and geotextile filters, developed a widely used design procedure for geotextile filters for drainage and permanent erosion-control applications. The level of design required depends on the critical nature of the project and the severity of the hydraulic and soil conditions. Especially

Analysis of Statically Indeterminate Beams by Force Method

While analyzing indeterminate structures, it is necessary to satisfy (force) equilibrium, (displacement) compatibility and force-displacement relationships. Force equilibrium is satisfied when the reactive forces hold the structure in stable equilibrium, as the structure is subjected to external loads. Displacement compatibility is satisfied when the various segments of the

Analysis & Design Report for Store & Generator Room

It is a frame structure single storey unit & includes areas for various purposes, such as transformer generator space. Ultimate Strength Design (USD) or Load and Resistance Factors Design (LRFD) method is used for structural design of all the components. The concrete used for all structural members should have a minimum 28 days cylinder crushing strength of 3,000 Psi.

Design of Water Tank using SAP2000

Select all beams in this storey. Select insertion point to center. Draw single element of area. Select area.

Design & Analysis of Stairs Using SAP2000

Option>preference> concrete frame design ACI-2003. Define> material concrete, modify, f’c =4 ksi, fy=60ksi. Define > area section, modify, name= slab6. Thickness= 6”

Search AboutCivil